Испытательная система CDM ESD
Руководство пользователя
Применимый LISUN модели: ESD-CDM
The ESD-CDM is used for CDM electrostatic testing and is fully compliant with ANSI/ESDA/JEDEC JS-002-2014, “For Electrostatic Discharge Sensitivity Testing—Charged Device Model (CDM)—Device Level.”The system primarily consists of three components: a DC high-voltage source, a test host, and an electrostatic test probe (including an attenuator). It is capable of performing electrostatic induction charging, electrostatic discharge, and discharge signal acquisition tests on charged device models (CDMs).
Обзор оборудования
Please open all packages and check the products against the packing list. If you notice any discrepancies, please contact us immediately.
Внешний вид оборудования:

= 1 * GB3① HBM/MM discharge tower.
= 2 * GB3② ESD main unit.
= 3 * GB3③ CDM discharge tower.
Note: The HBM/MM module and the CDM module can share the same main unit. This model includes only the CDM module.
Instrument Front Panel:
= 1 * GB3① Touchscreen LCD, used for setting and controlling discharge parameters.
= 2 * GB3② High-voltage sockets; the discharge tower’s high-voltage cables and control wires are connected to the main unit via these sockets. Ensure the high-voltage connectors are properly connected before turning on the instrument’s power. When inserting the high-voltage plug into the high-voltage socket, align it with the socket’s positioning pin, then gently push it all the way in and tighten the retaining cap. Note: Forcibly inserting the plug without aligning it with the positioning pin may damage the fine copper pins inside the high-voltage plug.

Задняя панель:
= 1 * GB3① Instrument power switch. = 2 * GB3② Power socket, with built-in fuse. = 3 * GB3③ RS232/RS485 communication port, for connecting to the CDM discharge tower.= 4 * GB3④ USB port, for connecting a mouse to control the touchscreen or a USB flash drive to upgrade the operating system. = 5 * GB3⑤ Grounding terminal; this terminal must remain properly grounded while the device is in use.

Discharge Tower:
= 1 * GB3① = 2 * GB3② = 3 * GB3③ Ground connection: When the equipment is in use, these three grounding ports must be connected to ground.
= 4 * GB3④ Discharge tower control wire connection.
= 5 * GB3⑤ High-voltage electrostatic discharge cable; the other end connects to the main unit of the Electrostatic Discharge Simulator.
= 6 * GB3⑥ Red and black wires connect to the test bench.
After the main unit and the discharge tower are connected, the setup will look as shown in the figure below:


Adjust the discharge tower height according to the sample:
= 1 * GB3① Limit block—this is the lowest adjustable position of the discharge tower;
for safety reasons, do not adjust it any lower. = 2 * GB3② Rotate to adjust the height of the discharge tower.
= 3 * GB3③ Rotate to adjust the forward and backward position of the discharge tower.

Program interface. You can set the electrostatic discharge voltage, polarity, interval time, number of discharges, and other parameters.

Эксплуатация оборудования
Complete all system wiring connections in accordance with the previous chapter and the relevant standards.
Install the test object and adjust the test stand, as well as the height and position of the discharge tower, according to the actual test object. You can first run a simulation test; the discharge tower will rise and lower automatically, and when it reaches its lowest point, it should make contact with the test point.
Set the test parameters in the program interface; once they are set, you can begin the test.
When the test is complete, replace the sample or shut down the machine.
Discharge Waveform Diagram


Что взять с собой
| 1 | ESD Host | 1 |
| 2 | CDM Discharge Tower | 1 |
| 3 | Шнур питания | 1 |
| 4 | Коаксиальный кабель | 1 |
| 5 | High-Voltage Connecting Cables | 2 |
| 6 | Провод заземления | 2 |
| 7 | CD (includes a digital user manual, warranty card, certificates, etc.) | 1 |
Решения для фотометрического, колориметрического тестирования и проверки безопасности светодиодов.
Система гониофотометра: LSG-6000, LSG-1890B или LSG-1800ACCD
Система для тестирования с использованием спектрорадиометра и интегрирующей сферы: LPCE-2 or LPCE-3
Компания LED Life поддерживает систему тестирования в соответствии со стандартом LM-84: LEDLM-84PL
Система испытаний на фотобиологическую радиационную безопасность: EN 62471-C или EN 62471-P
Система проверки запуска лампы, времени работы и мерцания: LSRF-3 и LSP-500VARC-Pst
Тестеры драйверов питания светодиодов: LS2090, M9822 и LSP-500VARC
Тестер уровня ИК | Тестер ударного действия пружинного молотка: IK07-10, IK01-06
Система электродинамического генератора вибрации: LVD-100KG-6D
Электроизмерительные приборы: LS9955, ZRS-3H, ZY-3, TTC-1
Решение для испытаний светодиодных светильников в экологической камере
Испытание на водонепроницаемость по стандартам IPX5 и IPX6: JL-56
Пылезащитные испытательные машины для IP5X и IP6X: SC-015
Камера высоких и низких температур и влажности: GDJS-015B
Машина для испытаний солевым туманом: YWX/Q-010
Камера для испытаний на старение УФ-лампы: UV-263LS
Камера для испытания на старение ксеноновой лампы: XD-80LS
Камера для испытаний на озон: OTC-150A
Испытательная камера для диоксида серы: SQ-010
Решения для тестирования электромагнитной совместимости (ЭМС) и электромагнитной совместимости (ЭМИ) люминесцентных и светодиодных светильников.
Система для проверки электромагнитной совместимости: EMI-9KB or EMI-9KA
Симулятор электростатического разряда: ESD61000-2
Измерение иммунитета к EFT: EFT61000-4
Генератор импульсов: SG61000-5
Генератор провалов и прерываний напряжения: CSS61000-11
Генератор кольцевых волн: RWG61000-12

www. Lisungroup.com
Поданные патенты
Все права защищены Lisun В группе
Может быть изменено без уведомления

中文简体